4-2 Jumper settings | 4-2 Jumper settings | ||
- | Jumpers JP1, JP2 set the interrupt priority | + | Jumpers JP1, JP2 set the interrupt priority for 68000MPU to level 2 or 4 (Source |
- | Set the priority level of the interrupt request signal | + | Set the priority level of the interrupt request signal |
- | | |JP1 Setting | + | | | JP1 | JP2 | |
- | |If you use Level 2 |1-2 jumper inserted between the socket | + | | Level 2 | 1-2 | 1-2 | |
- | |If you use Level 4 |2-3 jumper inserted between the socket | + | | Level 4 | 2-3 | 2-3 | |
- | Kyung-level priority interrupt request signal will be activated and allowed | + | Kernel-level priority interrupt request signal will be activated and allowed |
- | At level 2 interrupt request | + | Both jumpers must be set at the same level. |
+ | |||
+ | 4-3 Compatible X68000 hardware | ||
+ | |||
+ | *When used in CZ-600C, CZ-601C, CZ611C, CZ-602C, CZ-612C, CZ-603C, CZ-613C the device must be installed in I/0 slot 2. If you are planing | ||
- | Attached to a 4-3 X68000 series ● CZ-600C, CZ-601C, CZ611C, CZ-602C, CZ-612C, CZ-603C, CZ-613C installed in the case of the connector and attach to the l / 0 slot 2 again. | ||
- | CZ is already for sale ※-6BE2, CZ-6BE4, CZ-6BF1, CZ-6BM1, CZ-6BP1, CZ-board and 6BC1 (CZ-6BS1) If the combination is, I make sure before you install this board Please attach to / O slot 1. | ||
- | (CZ-6BG1, CZ-6BU1, CZ-6BL1, CZ-6BL2, CZ-board such as 6BN1 is in relation to the connector, in conjunction with this board please note that you can.) | ||
● CZ-652C, CZ-653C, CZ-662C, CZ-663C installed in the case, please attach to the I / 0 slot 4. | ● CZ-652C, CZ-653C, CZ-662C, CZ-663C installed in the case, please attach to the I / 0 slot 4. | ||
The board that use of the ※ I / O slot cover, I / O expansion box for the base unit and a computer (CZ-6EB1) because we have two ships with a slot cover for the slot corresponding to each Please use the cover. | The board that use of the ※ I / O slot cover, I / O expansion box for the base unit and a computer (CZ-6EB1) because we have two ships with a slot cover for the slot corresponding to each Please use the cover. |
x68000/cz-6bs1_-_genuine_sharp_scsi_board.txt · Last modified: 2019/08/27 20:45 by 127.0.0.1