x68000:hard_disk
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
x68000:hard_disk [2008/10/06 14:18] – computolio | x68000:hard_disk [2008/10/06 14:35] – computolio | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ===== X68000 Hard Disk ===== | ||
+ | |||
+ | ==== External HD connector ==== | ||
All models of X68000 (even SASI-based models) seem to have standard pinouts for the external hard disk connector: | All models of X68000 (even SASI-based models) seem to have standard pinouts for the external hard disk connector: | ||
Line 7: | Line 10: | ||
*Compact XVI, X68030, X68030 Compact: [[http:// | *Compact XVI, X68030, X68030 Compact: [[http:// | ||
+ | |||
+ | ==== Internal HD connector ==== | ||
All X68000 machines have a custom internal hard disk connector. The pinout for the SASI-based machines is as follows: | All X68000 machines have a custom internal hard disk connector. The pinout for the SASI-based machines is as follows: | ||
- | | + | ^Pin^Description^Pin^Description^ |
- | 2-DB1 | + | | |
- | 3-GND | + | | |
- | 4-DB2 | + | | |
- | 5-DB3 | + | | |
- | 6-DB4 | + | | |
- | 7-GND | + | | |
- | 8-DB5 | + | | |
- | 9-DB6 | + | | |
- | 10-DB7 | + | | |
- | 11-GND | + | | |
- | | + | |
- | | + | The pinout for SCSI-based machines: |
- | | + | |
- | | + | ^Pin^Description^Pin^Description^ |
- | | + | | 1 | DB0 | 14 |GND| |
- | | + | | 2 | DB1 | 15 |Unknown(Possibly |
- | | + | | 3 | GND | 16 |/BSY| |
- | | + | | 4 | DB2 | 17 |/ACK| |
- | | + | | 5 | DB3 | 18 |/RST| |
+ | | 6 | DB4 | 19 |/MSG| | ||
+ | | 7 | GND | 20 |/SEL| | ||
+ | | 8 | DB5 | 21 |/C/D| | ||
+ | | 9 | DB6 | 22 |REQ| | ||
+ | | 10 | DB7 | 23 |/I/O| | ||
+ | | 11 | GND | 24 |/I/O| | ||
+ | | 12 | PARITY | 25 |/I/O| | ||
+ | | 13 | +5V(Termination power) |
x68000/hard_disk.txt · Last modified: 2023/07/04 17:49 by TD-Linux