User Tools

Site Tools


x68000:cz-6bs1_-_genuine_sharp_scsi_board

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
x68000:cz-6bs1_-_genuine_sharp_scsi_board [2011/12/11 00:01] eidisx68000:cz-6bs1_-_genuine_sharp_scsi_board [2019/08/27 20:45] (current) – external edit 127.0.0.1
Line 14: Line 14:
  
 This board is made for X68000 personal workstation series (except CZ-623) and is attached to I/0 expansion slot. It can be used with SCSI MO drives, hard disks or CD-ROM/RW units. This board is made for X68000 personal workstation series (except CZ-623) and is attached to I/0 expansion slot. It can be used with SCSI MO drives, hard disks or CD-ROM/RW units.
-Smail Computer System Interface (SCSI) is the standard for data exchange between computer systems and peripherals. +Small Computer System Interface (SCSI) is the standard for data exchange between computer systems and peripherals. 
  
 1-2 Features 1-2 Features
Line 36: Line 36:
 **3. Installation notes**  **3. Installation notes** 
  
-When installing SCSI bracket pay attentions which one you need, because desktop models such as CZ-652C, CZ-653C, CZ-662C, CZ-663C have different dimensions. Switch the power switch to "Off" position, unplug the power cord and continue with the following steps: +  *When installing SCSI bracket pay attention to which one you need, because desktop models such as CZ-652C, CZ-653C, CZ-662C, CZ-663C have different dimensions. Switch the power switch to "Off" position, unplug the power cord and proceed with the installation. 
-  +  *Use this device only after installing the bracket and reading the instruction manual which came with your SCSI device.  
-● When using the Podo book, when read in conjunction Kuta instruction manual of the device SCSl.  +  *When not in use for long periods of time, remove the device from computer and put it into the supplied anti-static bag to protect it from electro static discharge.  
-When not in use for long Podo remove this from the computer when to protect it from ESD connector into the supplied anti-static bag.  +  *If the device has stopped workingplease contact the nearest customer service center.  
-Should ●and discontinue use when you feel a failure or abnormal gil of purchase, when you Kuta consult your nearest office or contact us.  +  *The SCSI interface and X68000 integrated SASI interfaceexcept for the CZ-623C, is different and SCSI interface is seen by Human68k as another interface that can interchange data betwean both interfaces. Devices which are connected to SASI interface and those which are connected to SCSI have different representation ID's. For exampleSASI (HD0 HD15) and SCSI (SCSI0 - SCSI7). Device may be marked with ID that it represents
-(Please note in particular our point).  +  *ID numbers for SCSI and SASI devices differ and they are physically different interfaces. As described above, SASI can handle up to 16 devicesSCSI can handle up to a maximum of 7 devicesA maximum of 23 devices can be connected in total.  
-SCSI interface and CZ ● hard disk interface - at × 68000 series except for the 623C, the interface of hard Gita with far different and specifications SCSl interface on Human68k is not arrived there as an interface of another system that interfaces the two In hard disks and hard disks connected to the SOSl interface is connected to a hard disk interface is a far different representationsfor example.  +This board was used without problems even after connecting the same amount of devices to SCSI and SASI interface at the same time
-The former hard simply (at sign HD0 HD15) and represent the case of the latter device or hard SCSl (at sign SCSl0 ~ SCSl7and is expressed +
-("Hard" may be marked with a symbol that case SCSl in the vicinity of. +
-SCSl ● ID numbers for hard disk interface and the interface is so physically different interfaces as described above, up to 16 hard disk interface (No. 0 to No. 15 from the device number), up to a maximum of seven SCSl interface (lD No. 6 from No. 0 to No.) No. 23 devices can be connected to the total.  +
-Takemasu was used without problems even among the same number of the device ID number that is connected to the interface SCSl lD number of devices that are connected to the hard disk interface Tay+
  
 **4. Names and handling procedures**  **4. Names and handling procedures** 
Line 52: Line 48:
 4-1 Names of Parts 4-1 Names of Parts
  
-{{:x68000:cz-6bs1_3.png|}}+{{:x68000:cz-6bs1_3_translated.png|}} 
 + 
 +4-2 Jumper settings 
 + 
 +Jumpers JP1, JP2 set the interrupt priority for 68000 CPU to level 2 or 4 (Source I/0 is available in two levels) and the board interprets from the jumper settings which one to use. Factory default is set to level 2. If you own the software, interrupt handling is set as follows.  
 +Set the priority level of the interrupt request signal with jumper JP2, set the interrupt priority level of the allowed signal with jumper JP1. The priority level can be selected as Level 2 or Level 4.
  
-Switch JP1 jumper setting on the switch on hoard 4-2, JP2 interrupt priority level and 4 as 68000MP ∪ He interrupts (from the I / 0 Surotsuto are two levels available) Set whether to use either This switch is used to. The included software interrupt processing in the setting of the switch so jacket does not use is optional. (Factory default is set to level for a bottle.)  +|  |  JP1  |  JP2  | 
-If you own a software interrupt processing is set as follows.  +|  Level   1-2  |  1- | 
-Set the priority level of the interrupt request signal switch jacket JP2, set the interrupt priority level of the signal allowed by the jacket Switch JP1. The priority level can be selected as a Level 2 or Level 4.+|  Level 4   2-3  |  2-3  |
  
-|  |JP1 Setting  |JP2 setting +Kernel-level priority interrupt request signal will be activated and allowed signal will be set to the same level.  
-|If you use a Level 2  |1-2 jumper inserted between the socket  |1-2 jumper inserted between the socket  | +Both jumpers must be set at the same level.
-|If you use four Rebaru  |2-3 jumper inserted between the socket  |2-3 jumper inserted between the socket  |+
  
-Kyung-level priority interrupt request signal will be activated and allowed is set to the same level.  +4-3 Compatible X68000 hardware
-At level 2 interrupt request level, such as how to use it at level and level interrupt is not allowed. +
  
-Attached to a 4-3 X68000 series ● CZ-600C, CZ-601C, CZ611C, CZ-602C, CZ-612C, CZ-603C, CZ-613C installed in the case of the connector and attach to the l / 0 slot 2 again +  *When used in tower models such as CZ-600C, CZ-601C, CZ611C, CZ-602C, CZ-612C, CZ-603C, CZ-613C the device must be installed in I/0 slot 2. If you are planing to use the CZ-6BS1 in conjunction with CZ-6BE2, CZ-6BE4, CZ-6BF1, CZ-6BM1, CZ-6BP1, CZ-6BC1, please populate I/O slot 1 before installing this boardThis board can also be used in conjunction with CZ-6BG1, CZ-6BU1, CZ-6BL1, CZ-6BL2, CZ-6BN1 boards
-CZ is already for sale ※-6BE2, CZ-6BE4, CZ-6BF1, CZ-6BM1, CZ-6BP1, CZ-board and 6BC1 (CZ-6BS1) If the combination is, I make sure before you install this board Please attach to / O slot 1.  +  *For desktop models such as CZ-652C, CZ-653C, CZ-662C, CZ-663C please install the device in I/slot 4. Since the introduction of I/O expansion box (CZ-6EB1) we ship two brackets. Please use the appropriate. However the bracket can not be used in CZ-600C, CZ-601C, CZ-611C, CZ-602C, CZ-612C, CZ-603C, CZ-613C alongside with CZ-6BF1, CZ-6BM1, CZ-6BC1 when combined with this board.
-(CZ-6BG1, CZ-6BU1, CZ-6BL1, CZ-6BL2, CZ-board such as 6BN1 is in relation to the connector, in conjunction with this board please note that you can. +
-● CZ-652C, CZ-653C, CZ-662C, CZ-663C installed in the case, please attach to the I / slot 4.  +
-The board that use of the ※ I / O slot cover, I / O expansion box for the base unit and a computer (CZ-6EB1) because we have two ships with a slot cover for the slot corresponding to each Please use the cover +
-However, for the computer (CZ-600C, CZ-601C, CZ-611C, CZ-602C, CZ-612C, CZ-603C, CZ-for 613C) I / O slot cover, CZ-6BF1, CZ-6BM1CZ- 6BC1 (board connector for connection to external devices) when combined with this board, etc. Please note that you can not use+
  
 "Connection Example" "Connection Example"
  
-{{:x68000:cz-6bs1_4.png|}}+{{:x68000:cz-6bs1_4_translated.png|}}
  
x68000/cz-6bs1_-_genuine_sharp_scsi_board.1323525675.txt.gz · Last modified: 2019/08/27 20:44 (external edit)