+ | ===== X68000 Hard Disk ===== | ||
+ | |||
+ | ==== External HD connector ==== | ||
+ | |||
+ | All X68000s (even the SASI-based models) seem to have standard pinouts for the external hard disk connector: | ||
+ | |||
+ | *Original model, Ace, Expert, Pro: [[http:// | ||
+ | |||
+ | *Super, XVI: Standard [[http:// | ||
+ | |||
+ | *Compact XVI, X68030, X68030 Compact: [[http:// | ||
+ | |||
+ | ==== Internal HD connector ==== | ||
+ | |||
+ | All X68000 machines have a custom internal hard disk connector. | ||
+ | |||
+ | The pinout for the SASI-based machines is as follows: | ||
+ | |||
+ | ^Pin^Description^Pin^Description^ | ||
+ | | 1 | DB0 | 11 |GND| | ||
+ | | 2 | DB1 | 12 |Unknown(Possibly for the HD access LED)| | ||
+ | | 3 | GND | 13 |/BSY| | ||
+ | | 4 | DB2 | 14 |/ACK| | ||
+ | | 5 | DB3 | 15 |/RST| | ||
+ | | 6 | DB4 | 16 |/MSG| | ||
+ | | 7 | GND | 17 |/SEL| | ||
+ | | 8 | DB5 | 18 |/C/D| | ||
+ | | 9 | DB6 | 19 |REQ| | ||
+ | | 10 | DB7 | 20 |/I/O| | ||
+ | |||
+ | The pinout for SCSI-based machines(Taken from http:// | ||
+ | |||
+ | ^Pin^Description^Pin^Description^ | ||
+ | | 1 | DB0 | 14 |/ATN| | ||
+ | | 2 | DB1 | 15 |GND| | ||
+ | | 3 | GND | 16 |HD Access LED| | ||
+ | | 4 | DB2 | 17 |/BSY| | ||
+ | | 5 | DB3 | 18 |/ACK| | ||
+ | | 6 | DB4 | 19 |GND| | ||
+ | | 7 | GND | 20 |/RST| | ||
+ | | 8 | DB5 | 21 |/MSG| | ||
+ | | 9 | DB6 | 22 |/SEL| | ||
+ | | 10 | DB7 | 23 |GND| | ||
+ | | 11 | GND | 24 |/C/D| | ||
+ | | 12 | PARITY | 25 |/REQ| | ||
+ | | 13 | +5V(Termination power) | ||
x68000/hard_disk.txt · Last modified: 2023/07/04 17:49 by TD-Linux