User Tools

Site Tools


x68000:soft_power_switch_troubleshooting_and_repair

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
x68000:soft_power_switch_troubleshooting_and_repair [2012/11/20 22:40] eidisx68000:soft_power_switch_troubleshooting_and_repair [2019/08/27 20:45] (current) – external edit 127.0.0.1
Line 1: Line 1:
-===== Soft power switch troubleshooting and repair =====+===== Soft-power troubleshooting and repair =====
  
-The following information is kind contribution by our forum members **Lydux** and **Caius**. This fix was applied to X68000 ExpertHD and SUPER.+The following information is kind contribution by our forum members **Lydux** and **Caius** and this fix was applied to X68000 SUPER and Expert HD.
  
-The symptomSystem powers on fine, but does not go into stand-by when the soft-power button is pressed. The screen fades, Power LED does not change from Green to Red and the system fan keeps spinning. The same happens while trying to use a regular ATX PSU.+**The symptoms:** X68000 powers on fine, but does not shut down when the soft-power button is pressed. The screen fades, Power LED does not change from Green to Red and the PSU fan keeps spinning. The same happens with a regular ATX PSU.
  
-The problem is almost sure located on the IO board.+If this is your case then the problem is almost surely located on the IO board
 + 
 +Here is the power on/off logic behind the /PSON signal (named CH2 in the schematics). Click on them to enlarge. 
 + 
 +{{:x68000:soft-power_schematic.png?400|}} 
 + 
 +**A condition using 4 signals is used to get the X68K turn on/off correctly :** 
 +  *Via the RTC (Real Time Clock) alarm signal (/RTC_ALARM) 
 +  *From the expansion bus (/EXPWON) 
 +  *Via the front power switch (/PSON) 
 +  *Via the soft-sequence signal from the system controller (/MPWOFF) 
 + 
 +In normal operation, all these 4 signals must go to logic High (+5v) to get a system shutdown. 
 +The problem might be due to a signal that is always stuck Low. 
 + 
 +If you look at the Buffered IO part in the schematics, 3 of these signals are connected to the MFP GPIP port. 
 + 
 +**They can be queried via software and are connected like this :** 
 + 
 +|/RTC_ALARM  |GPIP0 
 +|/EXPWON  |GPIP1 
 +|/PSON  |GPIP2 
 + 
 +**A program for testing these signals can be found here :** 
 + 
 +[[http://nfggames.com/X68000/Misc/Diagnostics/SoftPower%20Test%20Program/x68k_pwrtest.zip|X68k Power Test]] 
 + 
 +**Execute it more than one time. You should get :** 
 +  *RTC_ALARM = 1 or 0, depending on the current RTC configuration. 
 +  *EXPWON = 1 
 +  *PSON = 0 
 + 
 +**If RTC_ALARM always stays 0 :** 
 +  *Bad RTC chip (RP5C15) 
 + 
 +**If EXPWON = 0 :** 
 +  *Check the expansion riser, or remove it. 
 +  *Check the "Remote" plug on the back, if I remember right, it's also connected to this line. 
 + 
 +**If PSON = 1 :** 
 +  *Damaged resistor R54 (should act as pullup) 
 +  *Bad power switch 
 + 
 +**And if all is ok, it could be :** 
 +  *Bad IC28 (74LS08) (stuck output). 
 +  *Bad Q9 transistor (shorted). 
 +  *Bad C64 capacitor (generating noise). 
 +  *IC29 (74LS244) might have bad output on pin 5. 
 +  *The power signal from the main board, which I miss infos actually. A fix to this could be soldering a 10K ohm resistor between IC28 pin 10 and 14.
  
-Here is the power on/off logic behind the /PSON signal (named CH2 in the shematic) 
  
-{{:x68000:soft-power_schematic.png?900|}} 
x68000/soft_power_switch_troubleshooting_and_repair.1353415243.txt.gz · Last modified: 2019/08/27 20:44 (external edit)